Praevisio
A6120 Monitor Vibratio Seismica pro Casu Canalibus Duobus
Identificatio producti ex fonte officiali, directio applicationis et verificatio ordinandi pro A6120.
Ad Primum Aspectum
| Marca | Emerson (AMS/EPRO) |
|---|---|
| Modelus | A6120 |
| Typus Producti | Monitor Vibratio Seismica pro Casu Canalibus Duobus |
| Functio principalis | Monitors case seismic vibration and compares vibration parameters against alarm setpoints for machinery protection |
| Application / Compatible Series | AMS 6500 machinery protection systems for steam and gas turbines, compressors and hydro-turbomachinery |
Identificatio verificata
A6120 identificatur per totum modellem fabricantis et per unitatem photographatam.
Applicationis Concentratio
A6120 destinatur ad monitorandum vibrationem casus subiecti in turbinibus, compressoribus et aliis machinis rotativis.
Controllo ordinandi
A6120 debet concordare cum tota tabella nominis, revisione hardware et configuratione installata.
Product Overview
A6120 est Monitor Vibratio Seismica pro Casu Canalibus Duobus Emerson (AMS/EPRO), qui utitur ad monitorandum vibrationem casus subiecti in turbinibus, compressoribus et aliis machinis rotativis.
Key Functions
Identificatio verificata
A6120 identificatur per totum modellem fabricantis et per unitatem photographatam.
Applicationis Concentratio
A6120 destinatur ad monitorandum vibrationem casus subiecti in turbinibus, compressoribus et aliis machinis rotativis.
Controllo ordinandi
A6120 debet concordare cum tota tabella nominis, revisione hardware et configuratione installata.
Official Specifications
| Numerus Entratarum | Two independent channels |
|---|---|
| Typus Ingressus | Electro-dynamic (electro-mechanical), differential |
| Isolatio Intrantis | Separatus galvanice ab alimentatione electrica |
| Resistentia input | >100 kΩ |
| Input voltage range | -5 to +15 VDC |
| Ingressus frequentia ambitus | Cutoff inferior 1 vel 5 Hz; cutoff superior 50 ad 2000 Hz, regulabilis |
| Metric Measuring Range | 5 to 100 mm/s Vrms (±25 to ±500 μm) |
| English Measuring Range | 0.197 ad 3.937 in/s Vrms (±0.984 ad ±19.685 mils) |
| Standard Frequency Range | 10 ad 1000 Hz (VDI 2056, DIN 4566, ISO 3945) |
| Selectable Frequency Ranges | 5 ad 50 Hz, 10 ad 50 Hz, 50 ad 1000 Hz, vel 50 ad 1600 Hz |
| Lifting Coil Current | 0 ad 8 mA, configurable in 40 μA steps |
| Maximum Permissible Load | 3.4 kΩ ad 2 mA |
| Minimum Dynamic Input Voltage | 311 mV de pico a pico |
| Tensio Dinamica Maxima de Entrada | 9500 mV de pico a pico |
| Front Buffered Outputs | Duo; idem ad intrationes sensoris transductoris |
| Nivelis Exsulantis Anterioris | ±10 V cum onere >100 kΩ |
| Interfacing Configuratio | Faucis Mini-DIN cum RS-232 |
| Modi mensurae | Configurable en caliente; canales duales independientes; Vrms, cero-a-pico y pico-a-pico |
Origo ambitus: Enuntiationes technicae infra limitantur ad cartas protectionis Emerson AMS 6500 Classic. Disponibilitas commercialis, conditio et garantia sunt conditiones venditoris.
Quaestiones Frequentes
Quale configuratio de rack AMS 6500 es compatibile cum A6120?
Ute illud ut monitor unius-situs cum systemate AMS 6500 pro machinarum protectione, confirmans positionem cunei, revisionem hardware et configurationem installatam antequam substituatur.
Quae transducera ingeniarii cum A6120 uti possunt?
Ingressus differentiales ad transducera velocitatis electro-dynamicorum (electro-mechanicorum) destinati sunt; Emerson numeri partium sensorum 9266, 9267 et 9268 designat.
Ubi A6120 normaliter in machinis rotantibus applicatur?
Vibrationem sismicam casus in custodibus axis turbinum vaporis et gas, compressorum, hydro-turbomachinarum et aliarum machinarum rotantium criticarum monitorat.
Quid ante installationem A6120 verificandum est?
Confirmare positionem cunei 3U unius-situs, polaritatem sensoris, connexionem campi, ambitum ingressus, puncta allarmis et totam revisionem hardware antequam systema activatur.
Quot canales mensurationis A6120 praebet?
Duos canales mensurationis independentes cum ingressibus differentialibus electro-dynamicis praebet.
Quae parametra frequentialia ingressus pro A6120 disponibilia sunt?
Limita inferiora est seligibilis ad 1 aut 5 Hz, dum limita superiora reguatur ab 50 usque ad 2000 Hz.
Quae optiones output A6120 praebet?
Duae frontales output bufferatae transducunt input transductorum; output posteriores proportionales includunt signa currentis 0/4–20 mA et signa tensionis 0–10 V pro singulis canalibus.
Compatibility & Ordering Notes
Antequam Installatio
- Confronta l’intera targhetta A6120 e la sua revisione.
- Verificare exigentias systematis, rastri, portantis, sensoris, terminalis et connexorum in campo, ubi applicabile.
- Utere personis idoneis et procedura manutenzionis fabricantis.
Fons technicus officialis: Carduri de protecție Emerson AMS 6500 Classic