21000-16-10-15-070-03-02 Collecta corporum probae proximitatis
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Brevis Detalia
- DESCRIPTIO
- Applicationes
- Specificationes
- Commodum Competitivum
- Producta commendata
Conspectus
Locus Originis: |
Civitates Foederatae Americae |
Nomen Marcae: |
Bently Nevada |
Numerus Modeli: |
21000-16-10-15-070-03-02 |
Particularia Impressionis: |
Novus Originalis, Sigillatus a Fabrica |
Tempus Distributionis: |
5–7 dies |
Conditiones Pecuniarum: |
T/T |
Capacitas Suppeditandi: |
In stoce |
Brevis Detalia
|
Sensor cum Coniunctore: |
3300 XL 8mm probe |
|
Longitudo Cavi Sensoris: |
1,0 m (39 in) |
|
Adaptator Abstinentiae (Dimensio Optionis C): |
1.5 in |
|
Penetratio Sondae (Dimensio Optionis D): |
7.0 in |
|
Iuncturae: |
Unus obturatus 3/4-14 NPT Unus reductor 3/4-14 ad 1/2-14 NPT Unus prehensor cavi cum annulis elasticis pro sequentibus crassitudinibus cavorum: • 1/8 ad 3/16 pollices • 1/4 ad 5/16 pollices • 5/16 ad 3/8 pollices |
|
Fīlum montānse: |
3/4-14 NPT |
|
Dimensio: |
37 × 8,5 × 8,5 cm |
|
Pondus: |
1.3 KG |
DESCRIPTIO
The 21000-16-10-15-070-03-02 Collecta corporum probae proximitatis praebet firmum coniungendi modum pro probis 3300 XL 8 mm in machinis automatis monitorandis. Dotatus est cavo probe longo 1,0 m (39 pollicum), adaptatore intermedio 1,5 pollicis, et profunditate penetrationis probe 7,0 pollicum, 21000-16-10-15-070-03-02permittit praecisam mensuram vibrationis radialis in axis mediis. Corpus eius ex alluminio cum manica ex accipitro inox 304, fileto montandi NPT 3/4–14, et prehensoribus cavi pro filis diametri 1/8–3/8 pollicis, faciunt installationem celerem et minimam amissionem signi (< 0,05 V/mm). Approbatus a CSA et explosionis impervius, 21000-16-10-15-070-03-02systemata monitoriae automatizata adiuvat et substructionem tubularem facultativam pro axis longioribus quam septem pollices praebet, quae errorem mensurae ex vibratione a 0,8% ad 0,2% scalae plenae minuit.
Applicationes
Probas in Axis Medios Installe
The 21000-16-10-15-070-03-02cavitas probas 3300 XL in axis mediocriter longos disponit, penetrationem probae 7,0 pollicum praebens ad accuratam detectionem vibrationis radialis.
Integrare in systemata automata monitoriae
Cum cavo probe longo 1,0 m et prehensoribus cavi pro filis diametro 1/8–3/8 pollicis, 21000-16-10-15-070-03-02attenuationem signi parvam (<0,05 V/mm) in systematibus monitoriae automatizatis sinit.
Ad Varias Configurationes Montagii Accommoda
Montatio filetata 3/4-14 NPT et adaptator distantis 1,5 pollicis permittunt 21000-16-10-15-070-03-02in dispositionibus industrialibus compactis vel productis installari sine immutatione infrastructurae iam existentis.
Probas in Locis Periculosis Protege
Corpus ex alluminio cum tubulo ex accipitro inox 304 protegit 21000-16-10-15-070-03-02probes ab pulvere et humore, certificantes constantes lectiones in ambientibus industrialibus.
Specificationes
|
Materia: |
Corpus e alluminio cum vagina ex stadio inoxydabili 304 |
|
Massa (Pondus): |
1.1 kg (2.4 lb) typice, sine iuncturis |
Commodum Competitivum
Certificatus a CSA pro Locis Periculosis
The 21000-16-10-15-070-03-02est explosionis impervium et approbatum a CSA, subministrans supervisionem automatizatam in extremis condicionibus industrialibus.
Praecisissima radialis vibrationis mensura
7,0 in penetratio probae et 1,0 m cavis permittunt 21000-16-10-15-070-03-02praebere lectiones repetibiles cum errore ±0,2 % plenae scalae, ad normas API 670 satisfaciens.
Optiones Installationis Flexibilis
Optionalis tubus suffragans permittit 21000-16-10-15-070-03-02adaptari ad axes supra 7 in, minuens vibrationem pico-ad-picum de 70 % et servans accuratam mensuram.
Constructio Durabilis
Corpus ex alluminio cum tubo ex accipitro inox 304 certificat 21000-16-10-15-070-03-02resistere attritioni mechanicae et corrosioni, servans alignment probae intra 0,1 mm per longum tempus operationis.
Subsidium pro Dispositionibus Ad Hominem Factis
Bently Nevada praebet subsidia tubularia ad optionem pro 21000-16-10-15-070-03-02, quae permittunt installationes per internas domos cuneorum, dum error mensurae cumulativus sub 0,6 % scalae plenae manet.