Overview

Place of Origin:

USA

Brand Name:

HONEYWELL 

Model Number:

FC-SDI-1624 V1.1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Model:

FC-SDI-1624 V1.1

Product Type:

Safe Digital Input Module

Dimensions:

2 × 19 × 12.9 cm

Weight:

0.12 kg

Approvals:

CE; TUV; UL; CSA; FM

Space Requirements:

4 TE, 3 HE (4 HP, 3U)

Power Requirements:

5 VDC 8 mA; 24 VDC internal 110 mA; 24 VDC external 110 mA

Ripple Content (5 VDC):

<0.5 Vp-p (0–360 Hz)

Input Channels:

16

Maximum Input Voltage:

36 VDC

Input Current:

7 mA at 24 VDC

Input High Threshold:

>15 VDC

Input Low Threshold:

<9 VDC (I < 2 mA)

Input Delay:

~10 ms typical

Output Type:

24 VDC solid-state, short-circuit proof

Maximum Output Current:

450 mA

Max Load Capacitance:

32 μF

Voltage Drop:

<1.5 V at 450 mA

Module Connector Code:

Holes A5, C5

Chassis Connector Code:

Large pins A5, C5

Description

The Honeywell FC-SDI-1624 V1.1 is a safe digital input module in the safety manager system. This module primarily observes the on/off and powered/unpowered states of the switches and sends these states to the main processing unit.

Applications

Petroleum refinery: used in emergency shutdown circuits with fail-safe design ensuring shutdown signals remain reliable even if components fail

Long-distance pipeline station: used for remote valve monitoring, using high-density inputs to collect switch status along pipelines

Fine chemical plant: integrated into reactor pressure and level control chains, with diagnostics and anti-crosstalk to reduce wiring noise

Thermal power plant: applied in boiler fuel trip and turbine protection systems, with high diagnostics ensuring reliable interlock execution

Offshore LNG facility: used in gas release monitoring panels, with current-limited outputs driving explosion-proof switches in hazardous zones

Hazardous locations

The SDI-1624 module can also be used in non-hazardous areas for non-incendiary field circuits to Division 2 locations in compliance with FM 3611 (Class I, Division 2, Groups ABCD; Class II, Division 2, Groups FG).

Features

Multi-Type Input Support: Each channel accepts PNP, NPN, or dry contact signals.

Fast signal Acquisition: Ultra-low latency ensures reliable detection in safety systems.

Software Configurable: Input types and response times adjustable via system software.

Industrial Durability: Engineered for harsh environments and continuous operation.

Simplified Integration: Ideal for mixed-sensor installations in Honeywell control systems.

FAQ

Q: What is the number of input channels of the FC-SDI-1624 V1.1?
A: 16.

Q: What is the space specification of the FC-SDI-1624 V1.1?
A: 4 TE, 3 HE (4 HP, 3U).

Q: What is the high-level input threshold voltage of the FC-SDI-1624 V1.1?
A: Greater than 15 VDC.

Q: What is the maximum output current supported by the FC-SDI-1624 V1.1?
A: 450 mA.

Q: What is the maximum voltage drop at 450 mA for the FC-SDI-1624 V1.1?
A: Less than 1.5 V.