Siemens SIMATIC NET CP 343-1 Lean Communications Processor 6GK7343-1CX10-0XE0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC Industrial Automation

6GK7343-1CX10-0XE0 SIMATIC NET CP 343-1 Lean Communications Processor

The Siemens CP 343-1 Lean is a communications processor for SIMATIC S7-300 and C7-300 stations with a two-port PROFINET interface and Industrial Ethernet services.

At a Glance

Brand Siemens
Model 6GK7343-1CX10-0XE0
Product Type Industrial Ethernet communications processor
Core Function Connects SIMATIC S7-300 or C7-300 stations to Industrial Ethernet and PROFINET IO device networks
Application or Compatible Series SIMATIC S7-300 and C7-300 automation stations using TCP/IP, UDP, S7 communication or PROFINET IO device communication

Exact Identification

Match 6GK7343-1CX10-0XE0 character by character and confirm the complete SIMATIC NET CP 343-1 Lean Communications Processor designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The Siemens CP 343-1 Lean is a communications processor for SIMATIC S7-300 and C7-300 stations with a two-port PROFINET interface and Industrial Ethernet services.

Two front-panel RJ45 ports provide the Industrial Ethernet connection. SEND/RECEIVE services support TCP, ISO on TCP and UDP data exchange. The module can exchange up to 512 bytes of input and 512 bytes of output data as a PROFINET IO device.

Ordering focus: confirm the complete article number, hardware and firmware version, station type, IP configuration, communication services and configured data volume.
Key Functions

Two-Port PROFINET Interface

Two front-panel RJ45 ports provide the Industrial Ethernet connection.

Open Communication Resources

SEND/RECEIVE services support TCP, ISO on TCP and UDP data exchange.

PROFINET IO Device Integration

The module can exchange up to 512 bytes of input and 512 bytes of output data as a PROFINET IO device.

Official Specifications
Hardware Product Version 7
Firmware Version V3.0
Module Width 40 mm
Module Height 125 mm
Module Depth 120 mm
Net Weight 0.22 kg
Ethernet Ports 2 RJ45
Power Supply 24 V DC
Open Communication Connections 8 maximum
Maximum ISO-on-TCP User Data per Connection 8 KiB
Maximum TCP User Data per Connection 8 KiB
Maximum UDP User Data per Connection 2 KiB
S7 Communication Connections 4 maximum
Multicast Stations 8
PROFINET IO Device Input Data 512 bytes maximum
PROFINET IO Device Output Data 512 bytes maximum
Maximum PROFINET IO Device Submodules 32
Engineering Software STEP 7 V5.4 or later, or STEP 7 Professional V11 or later
Frequently Asked Questions

Which automation stations use 6GK7343-1CX10-0XE0?

Install the communications processor only in a compatible SIMATIC S7-300 or C7-300 station.

How many Ethernet ports are provided by 6GK7343-1CX10-0XE0?

The front panel provides two RJ45 Industrial Ethernet ports.

How many open communication connections can 6GK7343-1CX10-0XE0 manage?

The module supports up to eight SEND/RECEIVE open communication connections.

Can 6GK7343-1CX10-0XE0 operate as a PROFINET IO device?

Yes; it can exchange up to 512 bytes of input data and 512 bytes of output data in that role.

Which engineering software is required for 6GK7343-1CX10-0XE0?

Use STEP 7 V5.4 or later or STEP 7 Professional V11 or later.

What should be recorded before replacing 6GK7343-1CX10-0XE0?

Back up the station configuration, IP settings, connection resources, device name and communication blocks.

What should be tested after commissioning 6GK7343-1CX10-0XE0?

Verify the 24 V supply, both Ethernet ports, controller connection, data exchange and diagnostics.

Compatibility & Ordering Notes
Before ordering 6GK7343-1CX10-0XE0: confirm the complete article number, hardware and firmware version, station type, IP configuration, communication services and configured data volume.

Compatibility Checklist

  • Use only in a compatible S7-300 or C7-300 station.
  • Restore the original Ethernet and PROFINET settings.
  • Validate all configured open communication resources after replacement.
Hot Selling Models
M12MD1-PSC60B-S04G
08P1301/L
12M-XT-LS11-S4
3RV1011-0BA10
VPEV-1/8 150261
CHP24
BOS008M BOS 26K-PA-1QE-S4-C
3842501548 M12-M12
MZH-3-1.5-L-LED
SMEO-8E-K-24-S6
7999-40561-2331500
WL182P430
6GK1551-2AA00
GV2ME05 0.63-1A 034303
6ES7131-4BF00-0AA0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.