Siemens SIMOVERT MASTERDRIVES T300 Technology Board Kit 6SE7090-0XX87-4AH0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMOVERT MASTERDRIVES / SIMOREG DC-MASTER

6SE7090-0XX87-4AH0 SIMOVERT MASTERDRIVES T300 Technology Board Kit

The T300 kit provides a freely configurable technology processor with analog and digital I/O, two pulse-encoder connections, serial interfaces, two screened cables and the SE300 terminal block.

At a Glance

Brand Siemens
Model 6SE7090-0XX87-4AH0
Product Type Freely configurable T300 technology-processor board kit
Core Function Executes application-specific drive technology functions using configurable I/O and encoder interfaces
Application or Compatible Series SIMOVERT MASTERDRIVES CUVC and SIMOREG DC-MASTER 6RA70 drive systems

Exact Identification

Match 6SE7090-0XX87-4AH0 character by character and confirm the complete SIMOVERT MASTERDRIVES T300 Technology Board Kit designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The T300 kit provides a freely configurable technology processor with analog and digital I/O, two pulse-encoder connections, serial interfaces, two screened cables and the SE300 terminal block.

Application functions can be implemented with the T300 processor and its STRUC-programmed application memory. Analog, digital, encoder and serial signals support direct connection of technology functions to the drive application. The kit includes the SC58 and SC60 screened cables together with the rail-mounted SE300 terminal block.

Ordering focus: verify the complete kit article number, target drive platform, option-board slot, T300 program, SC58/SC60 cables, SE300 terminal and all field-signal assignments.
Key Functions

Freely Configurable Technology

Application functions can be implemented with the T300 processor and its STRUC-programmed application memory.

Integrated Plant Interfaces

Analog, digital, encoder and serial signals support direct connection of technology functions to the drive application.

Complete Terminal Kit

The kit includes the SC58 and SC60 screened cables together with the rail-mounted SE300 terminal block.

Official Specifications
Technology Processor Configuration Freely configurable
Analog Inputs and Outputs Integrated
Digital Inputs and Outputs Integrated
Pulse Encoder Connections 2
Serial Communications Integrated
Plant-Side Termination SE300 terminal block
Board-to-Terminal Cabling Screened round cables
Drive Installation Position Electronics box option-board slot 2
Application Programming Language STRUC
Included Cable Types SC58 and SC60
Terminal-Rail Standard 35 mm rail to DIN EN 50022-35
SE300 Dimensions 224 × 60 × 60 mm
Frequently Asked Questions

What components are included with 6SE7090-0XX87-4AH0?

The kit comprises the T300 technology board, SC58 and SC60 screened cables, the SE300 terminal block and hardware instructions.

Which drive slot is used by 6SE7090-0XX87-4AH0?

Install the technology board in option-board slot 2 of the applicable electronics box.

How are plant signals connected to 6SE7090-0XX87-4AH0?

Route them through the SE300 terminal block using the supplied screened round cables and the approved connector assignments.

Can pulse encoders be connected to 6SE7090-0XX87-4AH0?

Yes; two pulse-encoder connections are provided for application feedback signals.

How is the application configured for 6SE7090-0XX87-4AH0?

The technology program is created for the T300 environment using the STRUC language and the assigned program memory.

Where should the SE300 from 6SE7090-0XX87-4AH0 be mounted?

Snap it onto a 35 mm rail that conforms to DIN EN 50022-35 inside the protected cabinet.

What should be backed up before replacing 6SE7090-0XX87-4AH0?

Preserve the technology program, drive parameters, I/O assignment, encoder settings and installed hardware revision.

Compatibility & Ordering Notes
Before ordering 6SE7090-0XX87-4AH0: verify the complete kit article number, target drive platform, option-board slot, T300 program, SC58/SC60 cables, SE300 terminal and all field-signal assignments.

Compatibility Checklist

  • Confirm the installed drive platform, electronics box and option-board slot before fitting the T300 board.
  • Retain the SC58/SC60 cable routing and SE300 terminal assignments when exchanging hardware.
  • Back up the STRUC application and all drive or technology parameters before service.

Hot Selling Models
3RF2320-1AA04
27N 3048373
32/2 2754370
6ES5524-3UA13
3SB3000-4LD01-ZE:04
3RV1011-0GA20
CAD32P7
3RH1131-1AP00 3RT1916-1CD00
LUFN11 TeSys - 036517
3TH2022-0BB4 3TX4404-0A
6ES5318-8MA12
3RV1011-0KA25
SVS1-08-L4-S1-E0-C1
UKH240
STL58

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.