Siemens SIMOVERT MASTERDRIVES Digital Tachometer Interface 6SE7090-0XX84-3DB1
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens • SIMOVERT MASTERDRIVES
6SE7090-0XX84-3DB1 SIMOVERT MASTERDRIVES Digital Tachometer Interface
The digital tachometer interface is a SIMOVERT MASTERDRIVES board for HTL and TTL digital tachometer feedback with a published 400 kHz signal limit.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7090-0XX84-3DB1 |
| Product Type | Digital tachometer interface board |
| Core Function | Processes HTL or TTL digital tachometer feedback for drive control |
| Application or Compatible Series | SIMOVERT MASTERDRIVES feedback installations |
Exact Identification
Match 6SE7090-0XX84-3DB1 character by character and confirm the complete SIMOVERT MASTERDRIVES Digital Tachometer Interface designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The digital tachometer interface is a SIMOVERT MASTERDRIVES board for HTL and TTL digital tachometer feedback with a published 400 kHz signal limit.
The interface provides documented operating values for both HTL and TTL digital tachometer arrangements. Digital tachometer signals have a published limit frequency of 400 kHz. The board is specified for 0 to +55 °C operation and has IP00 protection.
Key Functions
HTL and TTL Feedback
The interface provides documented operating values for both HTL and TTL digital tachometer arrangements.
High-Frequency Signal Handling
Digital tachometer signals have a published limit frequency of 400 kHz.
Defined Environmental Data
The board is specified for 0 to +55 °C operation and has IP00 protection.
Official Specifications
| Internal Supply | 15 V DC, 160 mA |
|---|---|
| External Supply Range | 24 V DC, -16% to +25% |
| External Supply Current | 300 mA with HTL encoder; 150 mA with TTL encoder |
| Maximum Encoder-Supply Load | 300 mA with HTL encoder; 400 mA with TTL encoder |
| Encoder Input Current | 12 mA with HTL encoder; 42 mA with TTL encoder |
| Output Driver Current | 15 mA with HTL encoder; 20 mA with TTL encoder |
| Digital Signal Limit Frequency | 400 kHz |
| Operating Temperature | 0 to +55 °C |
| Storage and Transport Temperature | -25 to +70 °C |
| Environmental Classes | 3K3 humidity and 3C2 pollutant exposure |
| Degree of Protection | IP00 |
| Board Dimensions for the DB1 Variant | 160 x 96 x 56 mm |
Frequently Asked Questions
Which encoder signal types can be connected to 6SE7090-0XX84-3DB1?
The interface has published operating values for HTL and TTL digital tachometer signals.
What is the maximum signal frequency for 6SE7090-0XX84-3DB1?
The published digital-signal limit frequency is 400 kHz.
What external supply range is required for 6SE7090-0XX84-3DB1?
Use 24 V DC within the stated -16% to +25% tolerance.
How does HTL current demand differ from TTL on 6SE7090-0XX84-3DB1?
The documented external-supply current is 300 mA for HTL and 150 mA for TTL.
What operating temperature applies to 6SE7090-0XX84-3DB1?
The specified operating range is 0 to +55 °C.
What enclosure protection is provided by 6SE7090-0XX84-3DB1?
The board is specified with IP00 protection and requires suitable installation protection.
What should I check before installing 6SE7090-0XX84-3DB1?
Match the encoder signal type, 24 V DC supply tolerance, current demand and available board space.
Compatibility & Ordering Notes
Compatibility Checklist
- Use the interface in the intended SIMOVERT MASTERDRIVES feedback arrangement.
- Match the external supply and current data to the selected HTL or TTL encoder.
- Maintain the published environmental and installation-protection conditions.