Overview
SIEMENS SINAMICS G120D
6SL3525-0PE27-5AA1 PM250D Power Module
A regenerative 7.5 kW distributed drive power module for three-phase 380–500 V systems, with integrated Class A filtering and IP65 enclosure protection.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3525-0PE27-5AA1 |
| Product Type | PM250D Power Module |
| Core Function | Converts and regenerates drive power for distributed motor control |
| Application or Compatible Series | SINAMICS G120D distributed drive systems |
Engineering Fit
Designed for machine-level drive installations requiring regenerative operation close to the motor.
Configuration Focus
Match the control unit, motor data, supply range, connector set and permitted cable lengths.
Replacement Check
Verify the complete article number, FSC frame size and installed control-unit configuration.
Product Overview
This PM250D power module supplies a SINAMICS G120D distributed drive and returns braking energy to the line without a braking resistor. Its integrated Class A filter and enclosed design support installation in industrial machine environments.
The module provides a rated output of 7.5 kW at 400 V with 19 A rated output current, while supporting vector-control and V/f operating ranges for application-specific motor operation.
Key Functions
Regenerative Operation
Feeds braking energy back into the supply, reducing the need for an external braking resistor.
Distributed Drive Integration
Supports decentralized motor-control layouts in the SINAMICS G120D platform.
Motor-Control Range
Provides vector-control output up to 200 Hz and V/f output up to 650 Hz.
Industrial Enclosure
The IP65 enclosure supports installation near machinery when the specified connector and sealing requirements are maintained.
Official Specifications
| Input Supply | 3-phase AC, 380–500 V ±10% |
|---|---|
| Mains Frequency | 47–63 Hz |
| Rated Input Current | 17.7 A |
| Rated Output Power | 7.5 kW |
| Rated Output Voltage | 400 V |
| Rated Output Current | 19 A |
| Maximum Output Current | 38 A |
| Pulse Frequency | 4 kHz |
| Vector-Control Output Frequency | 0–200 Hz |
| V/f Output Frequency | 0–650 Hz |
| Overload Capability | 150% for 60 s; 200% for 3 s in a 300 s cycle |
| Motor Connector | HAN Q8 female |
| Shielded Motor Cable Length | Maximum 15 m |
| Unshielded Motor Cable Length | Maximum 30 m |
| Degree of Protection | IP65 / UL Type 3 |
| Frame Size | FSC |
| Dimensions | 445 × 210 × 220 mm |
| Net Weight | 8.5 kg |
| Operating Temperature | -10 to +55 °C |
| Efficiency | 0.97 |
Frequently Asked Questions
Can 6SL3525-0PE27-5AA1 return braking energy to the mains?
Yes, the regenerative design feeds braking energy back to the supply without an external braking resistor.
Which mains range is required for 6SL3525-0PE27-5AA1?
Use a three-phase 380–500 V AC supply within the specified ±10% tolerance.
What motor cable length is allowed with 6SL3525-0PE27-5AA1?
Use up to 15 m shielded cable or 30 m unshielded cable.
Which overload duty can 6SL3525-0PE27-5AA1 handle?
It supports 150% load for 60 seconds and 200% for 3 seconds within a 300-second cycle.
Does 6SL3525-0PE27-5AA1 need an external cabinet for protection?
Its IP65 enclosure supports machine-level installation when all connectors and seals are correctly fitted.
What should be checked before replacing 6SL3525-0PE27-5AA1?
Confirm the frame size, control unit, supply voltage, motor data and connector arrangement.
Which operating temperature applies to 6SL3525-0PE27-5AA1?
The specified operating range is -10 to +55 °C.
Compatibility & Ordering Notes
Compatibility Checks
- Confirm a three-phase 380–500 V AC supply.
- Check the motor cable against the 15 m shielded or 30 m unshielded limit.
- Verify the HAN Q4/2 line connector and HAN Q8 motor connector.
- Match the overload duty and control mode to the machine application.