siemens 6es7414 2xk05 0ab0 simatic s7 400 cpu 414 2 central processing unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S7-400 CPU 414-2 Central Processing Unit 6ES7414-2XK05-0AB0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC S7-400

6ES7414-2XK05-0AB0 SIMATIC S7-400 CPU 414-2 Central Processing Unit

The CPU 414-2 is a SIMATIC S7-400 central processing unit with 1 MB integrated work memory, one MPI/DP interface and a second PROFIBUS DP interface.

At a Glance

Brand Siemens
Model 6ES7414-2XK05-0AB0
Product Type SIMATIC S7-400 CPU 414-2 central processing unit
Core Function Executes S7-400 automation programs with integrated MPI/DP and PROFIBUS DP communications
Application or Compatible Series SIMATIC S7-400 controller racks engineered with STEP 7

Exact Identification

Match 6ES7414-2XK05-0AB0 character by character and confirm the complete SIMATIC S7-400 CPU 414-2 Central Processing Unit designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The CPU 414-2 is a SIMATIC S7-400 central processing unit with 1 MB integrated work memory, one MPI/DP interface and a second PROFIBUS DP interface.

The CPU provides separate 0.5 MB areas for program code and data within its 1 MB integrated work memory. The first interface supports MPI/DP at up to 12 Mbit/s, while the second interface is dedicated to PROFIBUS DP. CiR functionality allows supported distributed-I/O configuration changes while the controller remains in RUN.

Ordering focus: match the complete CPU 414-2 article number, hardware status 03, firmware V5.3, memory card, STEP 7 hardware catalog and both DP network configurations.
Key Functions

S7-400 Program Execution

The CPU provides separate 0.5 MB areas for program code and data within its 1 MB integrated work memory.

Dual PROFIBUS-Capable Interfaces

The first interface supports MPI/DP at up to 12 Mbit/s, while the second interface is dedicated to PROFIBUS DP.

Configuration in RUN Support

CiR functionality allows supported distributed-I/O configuration changes while the controller remains in RUN.

Official Specifications
Hardware Functional Status 03
Firmware Version V5.3
Isochronous Mode Supported for PROFIBUS only
Engineering Baseline STEP 7 V5.3 SP2 or higher with hardware update
CiR Synchronization Basic Load 100 ms
CiR Synchronization per I/O Byte 15 µs
Backplane-Bus Current at 5 V DC, Typical 0.9 A
Backplane-Bus Current at 5 V DC, Maximum 1.1 A
Backplane-Bus Current at 24 V DC, Maximum 300 mA; 150 mA per DP interface
Interface Current at 5 V DC, Maximum 90 mA at each DP interface
Typical Power Loss 4.5 W
Integrated Work Memory 1 MB
Program Work Memory 0.5 MB
Data Work Memory 0.5 MB
Work-Memory Expansion Not supported
Maximum FEPROM Load Memory 64 MB using a FLASH memory card
Integrated Load RAM 512 KB maximum
Maximum Expandable RAM Load Memory 64 MB using a RAM memory card
Battery Backup Supported for all data
Frequently Asked Questions

How is the work memory divided in 6ES7414-2XK05-0AB0?

The integrated 1 MB work memory is divided equally into 0.5 MB for program code and 0.5 MB for data.

Which fieldbus interfaces are built into 6ES7414-2XK05-0AB0?

The first interface operates as MPI/DP at up to 12 Mbit/s, and the second interface is PROFIBUS DP.

Which STEP 7 version is required to engineer 6ES7414-2XK05-0AB0?

Use STEP 7 V5.3 SP2 or later together with the required hardware update.

Can 6ES7414-2XK05-0AB0 run isochronous PROFIBUS operation?

Yes; isochronous mode is supported on PROFIBUS.

What memory-card capacity can be used with 6ES7414-2XK05-0AB0?

The load memory can be expanded to 64 MB with either the specified FLASH or RAM memory-card type.

How much backplane current should be allowed for 6ES7414-2XK05-0AB0?

Allow for up to 1.1 A from the 5 V backplane bus and up to 300 mA from the 24 V backplane bus.

What should be preserved before replacing 6ES7414-2XK05-0AB0?

Back up the STEP 7 project, program, hardware configuration, memory-card contents, MPI/DP addresses and PROFIBUS parameters.

Compatibility & Ordering Notes
Before ordering 6ES7414-2XK05-0AB0: match the complete CPU 414-2 article number, hardware status 03, firmware V5.3, memory card, STEP 7 hardware catalog and both DP network configurations.

Compatibility Checklist

  • Use the CPU in a compatible SIMATIC S7-400 rack with the documented system power supply.
  • Keep the STEP 7 project, hardware catalog entry and PROFIBUS configuration aligned with the installed firmware.
  • Back up the program and memory-card contents before exchanging the central processing unit.
Hot Selling Models
OG5060 OGSL00KG/V4A/US
3TX7002-3AB00
1734VTM
IG5318 IGB3008-BPKG/US
DN12 PN64 1.4408
KBB-16 R067201600
PLC-OPT-220DC/300DC/1
12P13G3/KS35L
3RQ3118-1AB01
M220-25130 M220-SE5489
3RV1011-0DA20
5SX22B10
3RT1926-1TR00
6ES7194-4AC00-0AA0
3RH2140-1BB40 3RH2911-1FB22 3RT2916-1EH00