SIEMENS • SIMATIC S7-400 / FM 458-1 DP
6DD1607-0AA1 SIMATIC FM 458-1 DP Application Module
The FM 458-1 DP is an application module for fast closed-loop control and calculation tasks, combining removable MMC program storage, a service interface, binary inputs and PROFIBUS DP communication.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DD1607-0AA1 |
| Product Type | High-performance application module |
| Core Function | Executes fast control and calculation tasks with PROFIBUS DP connectivity |
| Application or Compatible Series | SIMATIC S7-400 FM 458-1 DP control systems |
Exact Identification
Match 6DD1607-0AA1 character by character and confirm the complete SIMATIC FM 458-1 DP Application Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The FM 458-1 DP is an application module for fast closed-loop control and calculation tasks, combining removable MMC program storage, a service interface, binary inputs and PROFIBUS DP communication.
The application program is stored on supported 2 MB, 4 MB or 8 MB MMC cards. An RS-232 V.24 interface uses the DUST1 service protocol at 19.2 kbaud. Eight binary inputs and a PROFIBUS DP interface provide direct signal and distributed-system connectivity.
Key Functions
Removable Program Storage
The application program is stored on supported 2 MB, 4 MB or 8 MB MMC cards.
Local Service Access
An RS-232 V.24 interface uses the DUST1 service protocol at 19.2 kbaud.
Integrated Process Connections
Eight binary inputs and a PROFIBUS DP interface provide direct signal and distributed-system connectivity.
Official Specifications
| Supported MMC Capacities | 2 MB, 4 MB or 8 MB |
|---|---|
| Service Interface | RS-232 (V.24) |
| Service Protocol | DUST1 |
| Service-Port Data Rate | 19.2 kbaud |
| Binary Inputs | 8 |
| Binary-Input Isolation | Not isolated without optional interface modules |
| Permissible Input-Voltage Range | -1 V to +33 V |
| Nominal Input Voltage | 24 V |
| Input Signal Thresholds | 0 signal: -1 V to +6 V or open; 1 signal: +13.5 V to +33 V |
| Typical Input Current | 0 mA for signal 0; 3 mA for signal 1 |
| Maximum Input Delay | 100 µs per channel |
| PROFIBUS DP Rate | Up to 12 Mbaud |
| Typical 5 V Current Drain | 2.2 A |
| Backup-Battery Current | 15 µA at 3.4 V |
| Typical Power Loss | 11 W |
| Ambient Temperature Limit | 40 °C; 50 °C in the specified stand-alone arrangement |
| Slot Requirement | 1 slot |
| Dimensions | 260 x 197 x 20.32 mm |
| Weight | 1.0 kg |
Frequently Asked Questions
Which memory-card capacities can be used with 6DD1607-0AA1?
Supported MMC capacities are 2 MB, 4 MB and 8 MB.
How can a technician connect locally to 6DD1607-0AA1?
The service port is an RS-232 V.24 interface using DUST1 at 19.2 kbaud.
How many binary inputs are integrated in 6DD1607-0AA1?
The application module provides eight binary inputs.
Are the binary inputs on 6DD1607-0AA1 electrically isolated?
The inputs are not isolated unless suitable optional interface modules are used.
What PROFIBUS speed can 6DD1607-0AA1 support?
The PROFIBUS DP interface operates at up to 12 Mbaud.
Can 6DD1607-0AA1 operate at 50 °C?
Operation at 50 degrees Celsius is permitted only in the specified stand-alone arrangement with the listed interface modules and cable.
How much rack space is required for 6DD1607-0AA1?
The module occupies one slot.
Compatibility & Ordering Notes
Compatibility Checklist
- Retain a supported 2 MB, 4 MB or 8 MB MMC with the validated application program.
- Check whether optional interface modules provide the required binary-input isolation.
- For the higher temperature limit, keep the documented stand-alone module and cable arrangement.