Siemens SIMATIC NET CP 443-5 Extended Communication Processor 6GK7443-5DX04-0XE0
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens • SIMATIC NET CP 443-5 Extended
6GK7443-5DX04-0XE0 SIMATIC NET CP 443-5 Extended Communication Processor
The SIMATIC NET CP 443-5 Extended connects an S7-400 system to PROFIBUS DP for S5-compatible, PG/OP and S7 communication.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GK7443-5DX04-0XE0 |
| Product Type | S7-400 PROFIBUS communication processor |
| Core Function | Connects a SIMATIC S7-400 system to PROFIBUS DP and supports S5-compatible, PG/OP and S7 communication |
| Application or Compatible Series | SIMATIC S7-400 PROFIBUS communication and approved ET 200M external-DP-master applications |
Exact Identification
Match 6GK7443-5DX04-0XE0 character by character and confirm the complete SIMATIC NET CP 443-5 Extended Communication Processor designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The SIMATIC NET CP 443-5 Extended connects an S7-400 system to PROFIBUS DP for S5-compatible, PG/OP and S7 communication.
The processor is identified by Siemens for connecting SIMATIC S7-400 systems to PROFIBUS DP. The documented configuration path for this hardware generation uses STEP 7 Professional V11 SP1. DP diagnostic behavior differs by S7-compatible and DP-V1 mode and must be considered during commissioning.
Key Functions
S7-400 PROFIBUS Connection
The processor is identified by Siemens for connecting SIMATIC S7-400 systems to PROFIBUS DP.
Engineering Support
The documented configuration path for this hardware generation uses STEP 7 Professional V11 SP1.
Controlled Diagnostic Behavior
DP diagnostic behavior differs by S7-compatible and DP-V1 mode and must be considered during commissioning.
Official Specifications
| Product Type | CP 443-5 Extended communication processor |
|---|---|
| Controller Platform | SIMATIC S7-400 |
| Primary Network | PROFIBUS DP |
| S5-Compatible Communication | Supported |
| PG/OP Communication | Supported |
| S7 Communication | Supported |
| Referenced Firmware Level | Version 6.0 in Siemens compatibility information |
| Configuration Software | STEP 7 Professional V11 SP1 |
| Configuration Download Connections | MPI, Industrial Ethernet or PROFIBUS |
| Program Interface Blocks | Preprogrammed FCs/FBs available for some communication services |
| External DP Master for ET 200M Timestamping | Supported from CP 443-5 Extended V6.0 |
| DPV0 Diagnostics in S7-Compatible Mode | Forwarded to the user program after CPU STOP-to-RUN transition |
| DP-V1 Diagnostics in CPU STOP | Forwarded and require evaluation during module startup |
| CP Memory Reset with CPU RUN | Rejected |
| Memory-Reset Requirement | CPU configuration data must also be deleted |
| Siemens Successor | 6GK7443-5DX05-0XE0 |
Frequently Asked Questions
Which controller family is used with 6GK7443-5DX04-0XE0?
Use it with the compatible SIMATIC S7-400 station and the validated PROFIBUS project.
Which engineering package configures 6GK7443-5DX04-0XE0?
Use STEP 7 Professional V11 SP1 for the documented hardware-generation configuration path.
Can 6GK7443-5DX04-0XE0 be loaded through MPI or Industrial Ethernet?
Yes; MPI, Industrial Ethernet and PROFIBUS are documented download paths for the configuration data.
Can 6GK7443-5DX04-0XE0 be reset while the CPU is in RUN?
No; the processor rejects the reset while the CPU is in RUN mode.
What data must be handled with a processor reset for 6GK7443-5DX04-0XE0?
Clear the related CPU configuration data as well so the system does not retain inconsistent configuration information.
How are DP-V1 diagnostics handled by 6GK7443-5DX04-0XE0 while the CPU is stopped?
They are forwarded but must be evaluated appropriately when the module starts.
What should be verified after installing 6GK7443-5DX04-0XE0?
Check the configured bus parameters, communication services, diagnostic processing, network topology and controller startup sequence.
Compatibility & Ordering Notes
Compatibility Checklist
- Restore the original S7-400 and PROFIBUS hardware configuration.
- Use the documented Step 7 configuration path for this generation.
- Test diagnostics and communication services before returning the system to operation.