Siemens SIMATIC S7-400 6GK7443-1EX30-0XE1 CP 443-1 Industrial Ethernet Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
SIEMENS SIMATIC NET S7-400
6GK7443-1EX30-0XE1 CP 443-1 Industrial Ethernet Communication Processor
An S7-400 communication processor with a two-port 10/100 Mbit/s Industrial Ethernet switch, PROFINET IO controller functions and S7 communication services.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GK7443-1EX30-0XE1 |
| Product Type | CP 443-1 Industrial Ethernet Communication Processor |
| Core Function | Industrial Ethernet and PROFINET communication for S7-400 |
| Application or Compatible Series | SIMATIC S7-400 automation systems |
Engineering Fit
Designed to connect S7-400 stations to Industrial Ethernet for PROFINET IO control, S7 communication and open TCP, ISO-on-TCP or UDP services.
Replacement Focus
Match the hardware and firmware, rack slot, CPU compatibility, IP configuration, PROFINET device setup, open connections and security settings.
Product Overview
This communication processor adds two switched Industrial Ethernet ports to a SIMATIC S7-400 station. It supports PROFINET IO controller operation, S7 communication, SEND/RECEIVE services and open transport protocols.
Engineering and replacement work must preserve the module address, network identity, configured connections, access-control settings and PROFINET device assignments. The station power budget and permitted number of communication processors must also be observed.
Key Functions
Industrial Ethernet Connection
Provides two 10/100 Mbit/s RJ45 ports with an integrated switch for line or star network integration.
PROFINET IO Control
Operates as a PROFINET IO controller for distributed devices, including real-time communication functions.
S7 and Open Communication
Supports S7 communication plus ISO, TCP, ISO-on-TCP and UDP services.
Network Administration
Supports diagnostics, time synchronization, address assignment functions and access-control configuration.
Official Specifications
| Backplane Supply Voltage | 5 V DC |
|---|---|
| Typical Backplane Current | 1.4 A |
| Typical Power Loss | 7.25 W |
| Ethernet Interfaces | 2 × RJ45 with integrated switch |
| Ethernet Transmission Rate | 10 / 100 Mbit/s |
| PROFINET Function | IO controller |
| Maximum PROFINET IO Devices | 128 |
| Maximum IRT Devices | 64 |
| Maximum Open Communication Connections | 64 |
| Maximum S7 Connections | 128 |
| Maximum Active Multi-Protocol Connections | 128 |
| PROFINET Input / Output Area | 4 KB inputs and 4 KB outputs |
| Maximum Modules per CPU | 14 |
| Maximum PROFINET Controllers per CPU | 4 |
| Operating Temperature | 0 to 60 °C; up to 70 °C from hardware version 2 |
| Storage and Transport Temperature | -40 to +70 °C |
| Degree of Protection | IP20 |
| Mechanical Dimensions | 25 × 290 × 210 mm |
| Net Weight | Approximately 0.7 kg |
Official source: Siemens official technical data for 6GK7443-1EX30-0XE1.
Frequently Asked Questions
Can 6GK7443-1EX30-0XE1 operate as a PROFINET IO controller?
Yes. Configure the distributed devices, update times, device names and topology in the S7 project.
Which open communication protocols are available through 6GK7443-1EX30-0XE1?
The processor supports ISO, TCP, ISO-on-TCP and UDP services in addition to S7 communication.
How many PROFINET devices can 6GK7443-1EX30-0XE1 control?
The specified maximum is 128 IO devices, including up to 64 IRT devices, subject to the full station configuration.
What must be backed up before replacing 6GK7443-1EX30-0XE1?
Save the S7 hardware configuration, configured connections, IP parameters, device assignments and access-control settings.
Can 6GK7443-1EX30-0XE1 obtain network parameters through DHCP?
Yes. Use the supported address-assignment functions only when they match the plant network policy and project configuration.
How many 6GK7443-1EX30-0XE1 modules may be assigned to one CPU?
The documented maximum is 14 communication processors per CPU, with no more than four configured as PROFINET IO controllers.
What should I check if 6GK7443-1EX30-0XE1 loses communication after replacement?
Verify the rack slot, module address, IP settings, subnet, configured connections, PROFINET device names, access list and cabling.
Compatibility & Ordering Notes
Compatibility Checks
- Verify CPU compatibility, rack slot and module address.
- Restore IP parameters, subnet and configured connections.
- Confirm all PROFINET device names and IO assignments.
- Review access-control and time-synchronization settings.