siemens teleperm xp 6dp1232 8ba fum 232 temperature sensor conditioning module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens TELEPERM XP 6DP1232-8BA FUM 232 Temperature Sensor Conditioning Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens TELEPERM XP · Temperature Sensor Conditioning

Siemens 6DP1232-8BA FUM 232 Temperature Sensor Conditioning Module

FUM 232 module for conditioning Pt100 and thermocouple signals in TELEPERM XP and SPPA-T3000 automation systems.

At a Glance

Brand Siemens
Model 6DP1232-8BA
Product Type FUM 232 temperature-sensor conditioning module
Core Function Conditions Pt100 and thermocouple input signals
Compatible Series TELEPERM XP and SPPA-T3000

Exact Identification

Use the complete article number 6DP1232-8BA when matching the installed module.

Temperature Inputs

Designed for Pt100 resistance sensors and thermocouples.

System Fit

Match the module revision and I/O assignment to the existing automation station.

Product Overview

The Siemens 6DP1232-8BA is a FUM 232 signal-conditioning module for temperature measurements in TELEPERM XP and SPPA-T3000 process-control installations.

It accepts Pt100 resistance-sensor and thermocouple signals, with monitoring functions intended to support dependable acquisition of field temperature values.

Match the complete article number, hardware revision, sensor type, input allocation and terminal arrangement before replacing an installed module.

Key Functions

Resistance-Temperature Acquisition

Processes four-wire Pt100 sensor inputs for accurate resistance-based temperature measurement.

Thermocouple Signal Conditioning

Conditions thermocouple channels and supports fixed or variable reference-junction compensation.

Input Supervision

Monitors transmitter supply, measuring-range violations and sensor-circuit wire breaks.

Temperature Comparison

Supports differential-temperature evaluation where the configured application requires paired measurements.

Official Specifications

Pt100 Channel Capacity Up to 14 channels
Pt100 Sensor Connection Four-wire
Thermocouple Channel Capacity Up to 28 channels
Reference-Junction Compensation Fixed or variable
Transmitter-Supply Supervision Integrated supply-circuit monitoring
Measuring-Range Supervision Overrange and underrange detection
Sensor-Circuit Diagnostics Wire-break detection
Differential-Temperature Processing Temperature-difference evaluation between configured measurement inputs
Redundant Operating Configuration FUM 232 module redundancy
Official source:Siemens Industry catalog entry for 6DP1232-8BA. Commercial stock, warranty and shipping statements are seller terms.

Frequently Asked Questions

Can 6DP1232-8BA be used with both Pt100 sensors and thermocouples?

The module supports four-wire Pt100 inputs as well as thermocouple inputs within its documented channel capacities.

How many Pt100 channels can an engineer connect to 6DP1232-8BA?

Up to 14 four-wire Pt100 channels can be connected when the station is configured for resistance-temperature measurement.

What should be checked before replacing 6DP1232-8BA in a TELEPERM XP station?

Match the hardware revision, terminal assignment, configured sensor types and redundancy arrangement before installing the replacement.

Does 6DP1232-8BA detect an open sensor circuit?

The input supervision includes wire-break detection for supported sensor circuits.

Can 6DP1232-8BA monitor thermocouple reference-junction temperature?

Thermocouple operation supports fixed or variable reference-junction compensation according to the configured measurement setup.

Is 6DP1232-8BA suitable for differential-temperature measurement?

The module supports differential-temperature evaluation when the required input pairing is configured in the automation project.

Can 6DP1232-8BA be installed in a redundant measurement arrangement?

Redundant module operation is supported when the system architecture and project configuration provide the corresponding arrangement.

Compatibility & Ordering Notes

Before ordering 6DP1232-8BA: verify the installed FUM 232 revision, configured sensor mix, channel allocation, terminal wiring and redundancy requirement.

Compatibility Checklist for 6DP1232-8BA

  • Match the full article number and module revision.
  • Verify whether the field inputs are Pt100 sensors, thermocouples or a documented combination.
  • Confirm channel assignment, reference-junction method and monitoring configuration.
  • Check the existing terminal arrangement and redundant-system requirements before installation.
Hot Selling Models
140DDI35300
AT-UHD-EX-100CE-TX-PD
MILLENIUM3 CB12
ABB 3BSE021443R1 TU843
808613.1
NVT Nv-226j-pv
VKR020F300-FF
PSU100S 6EP1332-2BA20
PN 102097-00
GHG5117306R0001
PN:10937963
360G2-CRT12C-SM-PT
MTN693003
LA9D50978
RSN4004

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.